Solar Edge SE12.5K Inverter – RW0T0BNN4

SKU: F240D EAN: 5905951582382
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

RS485

AFCI

Weight 34,14 kg
Net price 756,23 
Gross

756,23 
Gross

In stock:

20 szt
Login to place an order

756,23 
Gross

In stock:

20 szt
Login to place an order

Datasheet Solar Edge SE12.5K - RW0T0BNN4 datasheet-solar-edge-se12-5k-rw0t0bnn4.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

RS485

AFCI

Weight 34,14 kg

SolarEdge Inverter Series SE12.5K – SE27.6K

The SE12.5K – SE27.6K inverter series from SolarEdge offers advanced technology that combines high efficiency, reliability, and smart energy management features. Ideal for commercial and industrial applications, they provide everything needed to maximize the performance of your PV system.

Main Features:

  • High Efficiency: Maximum efficiency of up to 98.3%, ensuring effective use of solar energy.
  • Quick Setup: Intuitive inverter startup directly from your smartphone using the SolarEdge SetApp application.
  • Module-Level Monitoring: Allows detailed management and performance analysis of each module in the system.
  • Versatile Installation: IP65 certification enables installation in both indoor and outdoor environments.
  • Advanced Energy Management: SolarEdge technology provides intelligent features that optimize the operation of the PV system.

Advantages of SolarEdge Inverters from the SE12.5K – SE27.6K Series:

Inverters from this series are distinguished by their exceptionally quiet operation, making them suitable for use in various environments, including near residential buildings. Equipped with constant voltage functionality, they allow for the design of longer strings, increasing the flexibility of solar system design. Additionally, selected models, such as SE25K and SE27.6K, feature optional integrated DC protection circuits that eliminate the need for additional fuses, significantly simplifying installation.

The high reliability of these devices is achieved through advanced safety features, such as arc protection and rapid shutdown capabilities in case of failure. Ethernet or Wi-Fi connectivity and compatibility with SolarEdge smart energy management systems make these inverters an excellent choice for large commercial and industrial installations.

Datasheet Solar Edge SE12.5K - RW0T0BNN4 datasheet-solar-edge-se12-5k-rw0t0bnn4.pdf

Technical Specification for SolarEdge SE12.5K-SE27.6K

Application for Inverters with Product Numbers
Parameter SE12.5K SE15K SE16K SE17K SE25K SE27.6K
Output
Nominal AC Power (VA) 12500 15000 16000 17000 25000 27600
Maximum AC Power (VA) 12500 15000 16000 17000 25000 27600
AC Output Voltage (V) 380 / 220; 400 / 230 380 / 220; 400 / 230 380 / 220; 400 / 230 380 / 220; 400 / 230 380 / 220; 400 / 230 380 / 220; 400 / 230
AC Output Voltage Range (V) 184 – 264.5 184 – 264.5 184 – 264.5 184 – 264.5 184 – 264.5 184 – 264.5
AC Frequency (Hz) 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5 50/60 ± 5
Maximum Continuous Output Current (A) 20 23 25.5 26 38 40
Supported Networks 3 / N / PE (star-grounded network with neutral wire) 3 / N / PE (star-grounded network with neutral wire) 3 / N / PE (star-grounded network with neutral wire) 3 / N / PE (star-grounded network with neutral wire) 3 / N / PE (star-grounded network with neutral wire) 3 / N / PE (star-grounded network with neutral wire)
Network Monitoring, Islanding Protection, Power Factor Yes Yes Yes Yes Yes Yes
THD < 3% < 3% < 3% < 3% < 3% < 3%
Input
Maximum DC Power (W) 16850 20250 21600 22950 33750 37250
Transformerless, Ungrounded Yes Yes Yes Yes Yes Yes
Maximum Input Voltage (V) 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc
Nominal Input Voltage (V) 750 Vdc 750 Vdc 750 Vdc 750 Vdc 750 Vdc 750 Vdc
Maximum Input Current (A) 21 22 23 23 37 40
Reverse Polarity Protection Yes Yes Yes Yes Yes Yes
Ground Fault Detection Sensitivity 700 kΩ Sensitivity 700 kΩ Sensitivity 700 kΩ Sensitivity 700 kΩ Sensitivity 350 kΩ Sensitivity 350 kΩ
Inverter Efficiency (%) 98.0 98.0 98.0 98.0 98.3 98.3
European Efficiency (%) 97.7 97.6 97.7 97.7 98.0 98.0
Night Consumption (W) < 2.5 < 2.5 < 2.5 < 2.5 < 4 < 4
Additional Features
Supported Communication Interfaces RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional) RS485, Ethernet, Wi-Fi (requires antenna), ZigBee (optional), GSM Cellular Network (optional)
Inverter Startup Using the SetApp mobile application with the built-in Wi-Fi access point for local connection Using the SetApp mobile application with the built-in Wi-Fi access point for local connection Using the SetApp mobile application with the built-in Wi-Fi access point for local connection Using the SetApp mobile application with the built-in Wi-Fi access point for local connection Using the SetApp mobile application with the built-in Wi-Fi access point for local connection Using the SetApp mobile application with the built-in Wi-Fi access point for local connection
Intelligent Energy Management Export Limitation Export Limitation Export Limitation Export Limitation Export Limitation Export Limitation
Arc Fault Protection Integrated, user-configurable (according to UL1699B) Integrated, user-configurable (according to UL1699B) Integrated, user-configurable (according to UL1699B) Integrated, user-configurable (according to UL1699B) Integrated, user-configurable (according to UL1699B) Integrated, user-configurable (according to UL1699B)
Rapid Disconnect Optional (Automatic upon AC grid disconnection) Optional (Automatic upon AC grid disconnection) Optional (Automatic upon AC grid disconnection) Optional (Automatic upon AC grid disconnection) Optional (Automatic upon AC grid disconnection) Optional (Automatic upon AC grid disconnection)
DC Protective Device (Optional)
2-Pole Disconnect Not Available Not Available Not Available Not Available 1000V / 40A 1000V / 40A
Surge Protection Not Available Not Available Not Available Not Available Type II, replaceable Type II, replaceable
DC Fuses Not Available Not Available Not Available Not Available Optional, 20A Optional, 20A
Compliance Not Available Not Available Not Available Not Available UTE-C15-712-1 UTE-C15-712-1
Standards Compliance
Safety IEC-62103 (EN50178), IEC-62109, AS3100 IEC-62103 (EN50178), IEC-62109, AS3100 IEC-62103 (EN50178), IEC-62109, AS3100 IEC-62103 (EN50178), IEC-62109, AS3100 IEC-62103 (EN50178), IEC-62109, AS3100 IEC-62103 (EN50178), IEC-62109, AS3100
Grid Connection VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW VDE-AR-N-4105, G59/3, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, BDEW
EMC IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12
RoHS Yes Yes Yes Yes Yes Yes
Mechanical Specification
Diameter of AC Output Grommet / Wire Cross Section 15-21mm / Solid wire 2.5-16 mm² 15-21mm / Solid wire 2.5-16 mm² 15-21mm / Solid wire 2.5-16 mm² 15-21mm / Solid wire 2.5-16 mm² 18-25mm / Solid wire 2.5-16 mm², Stranded wire 2.5-10 mm² 18-25mm / Solid wire 2.5-16 mm², Stranded wire 2.5-10 mm²
DC Input 2 pairs of MC4 2 pairs of MC4 2 pairs of MC4 2 pairs of MC4 3 pairs of MC4 3 pairs of MC4
DC Input with DC Protection Device Not Available Not Available Not Available Not Available Outer diameter of cable grommet 5-10 mm / Wire cross-section 0.5 – 13.5 mm² Outer diameter of cable grommet 5-10 mm / Wire cross-section 0.5 – 13.5 mm²
Dimensions (HxWxD) (mm) 540 x 315 x 260 540 x 315 x 260 540 x 315 x 260 540 x 315 x 260 540 x 315 x 260 540 x 315 x 260
Dimensions with DC Protection Device (H x W x D) (mm) Not Available Not Available Not Available Not Available 775 x 315 x 260 775 x 315 x 260
Weight (kg) 30.7 30.7 30.7 30.7 45 45
Weight with DC Protection Device Not Available Not Available Not Available Not Available 48 48
Operating Temperature Range (°C) -40 to +60 -40 to +60 -40 to +60 -40 to +60 -40 to +60 -40 to +60
Cooling Type User-replaceable Fan User-replaceable Fan User-replaceable Fan User-replaceable Fan User-replaceable Fan User-replaceable Fan
Noise Emission (dBA) < 50 < 50 < 50 < 50 < 55 < 55
Protection Class IP65 – suitable for outdoor or indoor use IP65 – suitable for outdoor or indoor use IP65 – suitable for outdoor or indoor use IP65 – suitable for outdoor or indoor use IP65 – suitable for outdoor or indoor use IP65 – suitable for outdoor or indoor use
Mounting Bracket included Bracket included Bracket included Bracket included Bracket included Bracket included

Official distribution

Other brands in our portfolio