DEYE SUN-10K-SG04LP3-EU Inverter

SKU: F20GZ2 EAN: 5905951584157
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

CAN

RS485

SPD Type II

SPD Typ III

Weight 47,1 kg
Net price 1 996,94 
Gross

1 996,94 
Gross

1 996,94 
Gross

Manual Deye SUN-10K-SG04LP3-EU manual-deye-sun-10k-sg04lp3-eu.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

CAN

RS485

SPD Type II

SPD Typ III

Weight 47,1 kg

Three-Phase Hybrid Inverter Deye SUN-5/6/8/10/12 K-SG04LP3-EU

The Deye SUN-5/6/8/10/12 K-SG04LP3-EU series of three-phase hybrid inverters is designed for advanced photovoltaic installations. Equipped with advanced energy management features and the capability to operate in both on-grid and off-grid modes, these inverters offer reliability and flexibility tailored to the needs of industrial users and households.

Key features of the Deye SUN-5/6/8/10/12 K-SG04LP3-EU inverters:

  • Support for unbalanced power – 100% support for unbalanced power for each phase, with a maximum output power of up to 50% of the rated capacity ensuring stable and efficient operation.
  • Flexible connections – the ability to connect to both direct and alternating current allows for the modernization of existing solar systems.
  • Multi-battery support – up to 16 batteries in parallel provide great scalability and reliability for energy storage.
  • Maximum charging/discharging current of 240A – high energy efficiency in the processes of charging and discharging batteries.
  • Low-voltage battery 48V – transformer isolation enhances the safety and reliability of the system’s operation.
  • 6 charging/discharging periods – flexible energy management tailored to different user needs.
  • Support for energy storage from a diesel generator – increases energy independence and allows integration with emergency power systems.

Who is this a good choice for?

The Deye SUN-5/6/8/10/12 K-SG04LP3-EU three-phase hybrid inverters are an ideal solution for large industrial and commercial installations, as well as for demanding households. With advanced energy management features, scalability, and high reliability, these devices will meet the needs of even the most demanding users.

Manual Deye SUN-10K-SG04LP3-EU manual-deye-sun-10k-sg04lp3-eu.pdf

Model SUN-5K-SG04LP3-EU SUN-6K-SG04LP3-EU SUN-8K-SG04LP3-EU SUN-10K-SG04LP3-EU SUN-12K-SG04LP3-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion
Battery Voltage Range (V) 40~60 40~60 40~60 40~60 40~60
Max Charging Current (A) 120 150 190 210 240
Max Discharging Current (A) 120 150 190 210 240
External Temperature Sensor Yes Yes Yes Yes Yes
Charging Curve 3 stages / equalization 3 stages / equalization 3 stages / equalization 3 stages / equalization 3 stages / equalization
Charging Strategy for Lithium-ion Battery Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS Self-adaptation to BMS
PV Input Data
Max Input Power DC (W) 6500 7800 10400 13000 15600
Rated Input Voltage PV (V) 550 (160~800) 550 (160~800) 550 (160~800) 550 (160~800) 550 (160~800)
Starting Voltage (V) 160 160 160 160 160
MPPT Voltage Range (V) 200-650 200-650 200-650 200-650 200-650
DC Voltage Range under Full Load (V) 350-650 350-650 350-650 350-650 350-650
PV Input Current (A) 13+13 13+13 13+13 26+13 26+13
Max PV ISC (A) 17+17 17+17 17+17 34+17 34+17
Number of MPPT / Strings per MPPT 2/1+1 2/1+1 2/1+1 2/2+1 2/2+1
AC Output Data
Rated AC Output and UPS Power (W) 5000 6000 8000 10000 12000
Max AC Output Power (W) 5500 6600 8800 11000 13200
Rated Output Current (AC) (A) 7.6 9.1 12.1 15.2 18.2
Max AC Current (A) 11.4 13.6 18.2 22.7 27.3
Max Continuous AC Current (A) 45 45 45 45 45
Peak Power (Off-grid) 2 times rated power, 10 S 2 times rated power, 10 S 2 times rated power, 10 S 2 times rated power, 10 S 2 times rated power, 10 S
Power Factor 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac 50/60Hz; 3L/N/PE 220/380, 230/400Vac 50/60Hz; 3L/N/PE 220/380, 230/400Vac 50/60Hz; 3L/N/PE 220/380, 230/400Vac 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three-phase Three-phase Three-phase Three-phase Three-phase
DC Injection Current (mA) TTHD < 3% (Linear Load < 1.5%) TTHD < 3% (Linear Load < 1.5%) TTHD < 3% (Linear Load < 1.5%) TTHD < 3% (Linear Load < 1.5%) TTHD < 3% (Linear Load < 1.5%)
Efficiency
Max Efficiency 97.60% 97.60% 97.60% 97.60% 97.60%
Euro Efficiency 97.00% 97.00% 97.00% 97.00% 97.00%
MPPT Efficiency 99.90% 99.90% 99.90% 99.90% 99.90%
Protection
Integration Lightning protection at the PV input, anti-islanding protection, reverse polarity protection at the PV string input, insulation resistance detection, residual current monitoring module, overcurrent protection at the output, short circuit protection at the output, surge protection Lightning protection at the PV input, anti-islanding protection, reverse polarity protection at the PV string input, insulation resistance detection, residual current monitoring module, overcurrent protection at the output, short circuit protection at the output, surge protection Lightning protection at the PV input, anti-islanding protection, reverse polarity protection at the PV string input, insulation resistance detection, residual current monitoring module, overcurrent protection at the output, short circuit protection at the output, surge protection Lightning protection at the PV input, anti-islanding protection, reverse polarity protection at the PV string input, insulation resistance detection, residual current monitoring module, overcurrent protection at the output, short circuit protection at the output, surge protection Lightning protection at the PV input, anti-islanding protection, reverse polarity protection at the PV string input, insulation resistance detection, residual current monitoring module, overcurrent protection at the output, short circuit protection at the output, surge protection
Output Overvoltage Protection DC type II/AC type III DC type II/AC type III DC type II/AC type III DC type II/AC type III DC type II/AC type III
Certifications and Standards
Grid Regulation CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
EMC Safety / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (°C) -45~60℃, >45℃ derating -45~60℃, >45℃ derating -45~60℃, >45℃ derating -45~60℃, >45℃ derating -45~60℃, >45℃ derating
Cooling Intelligent Cooling Intelligent Cooling Intelligent Cooling Intelligent Cooling Intelligent Cooling
Noise (dB) <45 dB <45 dB <45 dB <45 dB <45 dB
BMS Communication RS485; CAN RS485; CAN RS485; CAN RS485; CAN RS485; CAN
Weight (kg) 33.6 33.6 33.6 33.6 33.6
Size (mm) 422 W x 699.3 H x 279 D 422 W x 699.3 H x 279 D 422 W x 699.3 H x 279 D 422 W x 699.3 H x 279 D 422 W x 699.3 H x 279 D
Protection Class IP65 IP65 IP65 IP65 IP65
Installation Style Wall-mounted Wall-mounted Wall-mounted Wall-mounted Wall-mounted
Warranty
Warranty 5 years 5 years 5 years 5 years 5 years

Official distribution

Other brands in our portfolio