SOLAR EDGE SE50K Inverter

SKU: F240L EAN: 5905951580531
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

RS485

SPD Type II

AFCI

Weight 19,12 kg
Net price 564,90 
Gross

564,90 
Gross

In stock:

19 szt
Login to place an order

564,90 
Gross

In stock:

19 szt
Login to place an order

Datasheet Solar Edge SE50K - RW00IBNQ4 datasheet-solar-edge-se50k-rw00ibnq4.pdf

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

Warranty

Net width

Net depth

Net height

RS485

SPD Type II

AFCI

Weight 19,12 kg

SolarEdge Inverters SE50K / SE66.6K / SE90K / SE100K / SE120K Series

The SE50K / SE66.6K / SE90K / SE100K / SE120K inverter series is designed for large photovoltaic installations, delivering unparalleled performance, safety, and ease of use. With a modular design and advanced features, these devices meet the highest standards in the PV industry.

Key Features:

  • Pre-commissioning function: Automatic validation of system components during the installation phase, reducing installation and commissioning time.
  • Easy installation: The modular, lightweight design allows for installation by a two-person team.
  • Advanced safety: Built-in temperature sensors and an arc fault protection feature with optional rapid shutdown.
  • Independent unit operation: Synergistic units minimize downtime and simplify maintenance.
  • Integrated protections: Type 2 DC surge protective devices and Type 2 AC SPD for maximum safety.

Why choose an inverter from the SE50K / SE66.6K / SE90K / SE100K / SE120K series?

Inverters from this series offer real-time monitoring, providing greater control over system performance and quick detection of potential issues. The built-in PID reduction feature ensures maximum efficiency, while compatibility with advanced SolarEdge energy management systems makes them a forward-thinking choice.

With their lightweight design and ease of installation, these devices are suitable for both large commercial and industrial installations. The built-in surge protection, optional DC emergency switches, and advanced safety features ensure reliability and durability at the highest level. This is the perfect solution for investors looking for efficient and versatile inverters for large PV systems.

Datasheet Solar Edge SE50K - RW00IBNQ4 datasheet-solar-edge-se50k-rw00ibnq4.pdf

Technical Specifications of SolarEdge SE50K – SE120K
  SExxK-xxx0Ixxxx SExxKxxx8Ixxxx
Parameter SE50K (400V grid) SE66.6K (400V grid) SE90K (400V grid) SE100K (400V grid) SE120K (480V grid)
Output
Rated Active Output Power (W) 50000 66600 90000 100000 120000
Maximum Apparent Output Power (VA) 50000 66600 90000 100000 120000
Output Voltage AC — Phase–Phase/Phase–Neutral (Nominal) (Vac) 380 / 220, 400 / 230 380 / 220, 400 / 230 380 / 220, 400 / 230 380 / 220, 400 / 230 480 / 277
Output Voltage AC — Phase–Phase/Phase–Neutral Range (Vac) 304 – 437 / 176 – 253; 320 – 460 / 184 – 264.5 304 – 437 / 176 – 253; 320 – 460 / 184 – 264.5 304 – 437 / 176 – 253; 320 – 460 / 184 – 264.5 304 – 437 / 176 – 253; 320 – 460 / 184 – 264.5 432 – 529 / 249 – 305
AC Frequency (Hz) 50/60 ± 5% 50/60 ± 5% 50/60 ± 5% 50/60 ± 5% 50/60 ± 5%
Max Continuous Output Current (A) 72.5 96.5 130.5 145.0 145.0
AC Output Connections 3W + PE, 4W + PE 3W + PE, 4W + PE 3W + PE, 4W + PE 3W + PE, 4W + PE 3W + PE, 4W + PE
Supported Networks WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT
Max Residual Current (mA) 200 200 300 300 300
Network Monitoring, Islanding Protection, Configurable Power Factor, Country-Specific Threshold Values Yes Yes Yes Yes Yes
Total Harmonic Distortion (THD) (%) ≤ 3% ≤ 3% ≤ 3% ≤ 3% ≤ 3%
Power Factor Range ±0.8 to ±1 ±0.8 to ±1 ±0.8 to ±1 ±0.8 to ±1 ±0.8 to ±1
Input
Max DC Power (STC Module) Inverter / Synergy Unit (W) 75000 / 37500 100000 / 50000 135000 / 45000 150000 / 50000 180000 / 60000
Transformerless, ungrounded Yes Yes Yes Yes Yes
Maximum Input Voltage DC+ to DC- (VDC) 1000 1000 1000 1000 1000
Nominal Input Voltage DC+ to DC- (VDC) 750 750 750 750 850
Max Input Current (ADC) 2 x 36.25 2 x 48.25 3 x 43.5 3 x 48.25 3 x 48.25
Reverse Polarity Protection Yes Yes Yes Yes Yes
Ground Fault Detection Sensitivity 167 kΩ per synergy unit Sensitivity 167 kΩ per synergy unit Sensitivity 167 kΩ per synergy unit Sensitivity 167 kΩ per synergy unit Sensitivity 167 kΩ per synergy unit
Maximum Inverter Efficiency (%) 98.3 98.3 98.3 98.3 98.1
European Efficiency (weighted) (%) 98 98 98 98 98
Nighttime Power Consumption (W) < 8 < 8 < 12 < 12 < 12
Additional Functions
Supported Communication Interfaces 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional)
Smart Energy Management Export Limitation Export Limitation Export Limitation Export Limitation Export Limitation
Inverter Startup SetApp mobile application using the built-in Wi-Fi access point for establishing local connections SetApp mobile application using the built-in Wi-Fi access point for establishing local connections SetApp mobile application using the built-in Wi-Fi access point for establishing local connections SetApp mobile application using the built-in Wi-Fi access point for establishing local connections SetApp mobile application using the built-in Wi-Fi access point for establishing local connections
Arc Fault Protection Built-in, user-configurable (according to UL1699B) Built-in, user-configurable (according to UL1699B) Built-in, user-configurable (according to UL1699B) Built-in, user-configurable (according to UL1699B) Built-in, user-configurable (according to UL1699B)
Rapid Shutdown Optional (Automatic upon disconnection from AC grid) Optional (Automatic upon disconnection from AC grid) Optional (Automatic upon disconnection from AC grid) Optional (Automatic upon disconnection from AC grid) Optional (Automatic upon disconnection from AC grid)
PID Controller Night hours, built-in Night hours, built-in Night hours, built-in Night hours, built-in Night hours, built-in
RS485 Surge Protection (Ports 1+2) Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated
DC Surge Protection Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated
AC Surge Protection Type II, field-replaceable, optional Type II, field-replaceable, optional Type II, field-replaceable, optional Type II, field-replaceable, optional Type II, field-replaceable, optional
DC Fuses (Single Pole) 25 A, optional 25 A, optional 25 A, optional 25 A, optional 25 A, optional
DC Disconnect Switch Optional Optional Optional Optional Optional
Compliance with Standards
Safety IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100
Grid Connection Standards EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019
EMC IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12
RoHS Yes Yes Yes Yes Yes
Installation Specifications
Number of Synergy Units per Inverter 2 2 3 3 3
AC Cable Cross-Section and Outer Diameter (mm²) Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm
DC Input: Inverter / Synergy Unit 8/4 pairs of MC4 | Gland, 2 pairs / 1 pair, cross-section up to 50 mm², aluminum or copper, outer cable diameter 12-20 mm 8/4 pairs of MC4 | Gland, 2 pairs / 1 pair, cross-section up to 50 mm², aluminum or copper, outer cable diameter 12-20 mm 12/4 pairs of MC4 | Gland, 3 pairs / 1 pair, cross-section up to 50 mm², aluminum or copper, outer cable diameter 12-20 mm 12/4 pairs of MC4 | Gland, 3 pairs / 1 pair, cross-section up to 50 mm², aluminum or copper, outer cable diameter 12-20 mm 12/4 pairs of MC4 | Gland, 3 pairs / 1 pair, cross-section up to 50 mm², aluminum or copper, outer cable diameter 12-20 mm
Dimensions (H x W x D) (mm) Synergy Unit: 558 x 328 x 273 mm; Synergy Manager: 360 x 560 x 295 mm Synergy Unit: 558 x 328 x 273 mm; Synergy Manager: 360 x 560 x 295 mm Synergy Unit: 558 x 328 x 273 mm; Synergy Manager: 360 x 560 x 295 mm Synergy Unit: 558 x 328 x 273 mm; Synergy Manager: 360 x 560 x 295 mm Synergy Unit: 558 x 328 x 273 mm; Synergy Manager: 360 x 560 x 295 mm
Weight (kg) Synergy Unit: 32 kg; Synergy Management Unit: 18 kg Synergy Unit: 32 kg; Synergy Management Unit: 18 kg Synergy Unit: 32 kg; Synergy Management Unit: 18 kg Synergy Unit: 32 kg; Synergy Management Unit: 18 kg Synergy Unit: 32 kg; Synergy Management Unit: 18 kg
Operating Temperature Range (°C) -40 to +60 -40 to +60 -40 to +60 -40 to +60 -40 to +60
Cooling Fan (replaceable) Fan (replaceable) Fan (replaceable) Fan (replaceable) Fan (replaceable)
Noise (dBA) < 67 < 67 < 67 < 67 < 67
Protection Class IP65 — for outdoor and indoor use IP65 — for outdoor and indoor use IP65 — for outdoor and indoor use IP65 — for outdoor and indoor use IP65 — for outdoor and indoor use
Installation Mounting bracket included Mounting bracket included Mounting bracket included Mounting bracket included Mounting bracket included

Official distribution

Other brands in our portfolio