| SOFAR 3.3KTLX-G3 |
SOFAR 4.4KTLX-G3 |
SOFAR 5.5KTLX-G3 |
SOFAR 6.6KTLX-G3 |
SOFAR 8.8KTLX-G3 |
SOFAR 11KTLX-G3 |
SOFAR 12KTLX-G3 |
| Recommended Max PV Input Power (Wp) |
4500 |
6000 |
7500 |
9000 |
12000 |
15000 |
18000 |
| Number of MPPTs |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
| Number of DC Inputs |
1/1 |
1/1 |
1/1 |
1/1 |
1/1 |
1/1 |
2/1 |
| Max Input Voltage (V) |
1100 |
1100 |
1100 |
1100 |
1100 |
1100 |
1100 |
| Starting Voltage (V) |
160 |
160 |
160 |
160 |
160 |
160 |
160 |
| Nominal Input Voltage (V) |
650 |
650 |
650 |
650 |
650 |
650 |
650 |
| MPPT Operating Voltage Range (V) |
140-1000 |
140-1000 |
140-1000 |
140-1000 |
140-1000 |
140-1000 |
140-1000 |
| MPPT Voltage Range at Full Power (V) |
160-850 |
190-850 |
240-850 |
290-850 |
380-850 |
420-850 |
460-850 |
| Max MPPT Input Current (A) |
15/15 |
15/15 |
15/15 |
15/15 |
15/15 |
15/15 |
30/15 |
| Max Short-Circuit Current on MPPT (A) |
22.5/22.5 |
22.5/22.5 |
22.5/22.5 |
22.5/22.5 |
22.5/22.5 |
22.5/22.5 |
45/22.5 |
| Rated Power (W) |
3000 |
4000 |
5000 |
6000 |
8000 |
10000 |
12000 |
| Max AC Power (VA) |
3300 |
4400 |
5500 |
6600 |
8800 |
11000 |
13200 |
| Max Output Current (A) |
4.8 |
6.4 |
8.0 |
9.6 |
12.8 |
15.9 |
19.1 |
| Nominal Grid Voltage (Vac) |
3/N/PE, 230 / 400 |
3/N/PE, 230 / 400 |
3/N/PE, 230 / 400 |
3/N/PE, 230 / 400 |
3/N/PE, 230 / 400 |
3/N/PE, 230 / 400 |
3/N/PE, 230 / 400 |
| Grid Voltage Range (Vac) |
310 – 480 Vac (according to local standards) |
310 – 480 Vac (according to local standards) |
310 – 480 Vac (according to local standards) |
310 – 480 Vac (according to local standards) |
310 – 480 Vac (according to local standards) |
310 – 480 Vac (according to local standards) |
310 – 480 Vac (according to local standards) |
| Nominal Grid Frequency (Hz) |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
50 Hz / 60 Hz |
| Grid Frequency Range (Hz) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
45 – 55 Hz / 55 – 65 Hz (according to local standards) |
| Active Power Regulation Range |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
| THDi |
<3% |
<3% |
<3% |
<3% |
<3% |
<3% |
<3% |
| Power Factor |
1 default (adjustable +/-0.8) |
1 default (adjustable +/-0.8) |
1 default (adjustable +/-0.8) |
1 default (adjustable +/-0.8) |
1 default (adjustable +/-0.8) |
1 default (adjustable +/-0.8) |
1 default (adjustable +/-0.8) |
| Max Efficiency (%) |
98.40% |
98.40% |
98.40% |
98.40% |
98.50% |
98.50% |
98.50% |
| European Efficiency (%) |
97.50% |
97.50% |
97.50% |
97.50% |
98.00% |
98.00% |
98.00% |
| DC Reverse Polarity Protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Island Mode Protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Residual Current Protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Ground Fault Detection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| PV String Fault Monitoring |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Energy Outflow Blocking |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| DC Switch |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| SPD Input/Output |
PV: type II standard, AC: type II standard |
PV: type II standard, AC: type II standard |
PV: type II standard, AC: type II standard |
PV: type II standard, AC: type II standard |
PV: type II standard, AC: type II standard |
PV: type II standard, AC: type II standard |
PV: type II standard, AC: type II standard |
| Standard Communication Mode |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
RS485 / WiFi / Bluetooth, optionally: Ethernet |
| Ambient Temperature Range |
-30°C … +60°C |
-30°C … +60°C |
-30°C … +60°C |
-30°C … +60°C |
-30°C … +60°C |
-30°C … +60°C |
-30°C … +60°C |
| Night Power Consumption (W) |
<1 |
<1 |
<1 |
<1 |
<1 |
<1 |
<1 |
| Topology |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
| Protection Rating |
IP65 |
IP65 |
IP65 |
IP65 |
IP65 |
IP65 |
IP65 |
| Permissible Relative Humidity Range |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
0 – 100% |
| Max Operating Height |
4000 m |
4000 m |
4000 m |
4000 m |
4000 m |
4000 m |
4000 m |
| Noise |
<40 dB |
<40 dB |
<40 dB |
<40 dB |
<40 dB |
<40 dB |
<40 dB |
| Weight (kg) |
15 |
15 |
15 |
15 |
17 |
17 |
17 |
| Cooling |
Natural |
Natural |
Natural |
Natural |
Natural |
Natural |
| Dimensions (mm) |
430*375*179 |
430*375*179 |
430*375*179 |
430*375*179 |
430*375*179 |
430*375*179 |
430*375*179 |
| Display |
LCD, application via Bluetooth |
LCD, application via Bluetooth |
LCD, application via Bluetooth |
LCD, application via Bluetooth |
LCD, application via Bluetooth |
LCD, application via Bluetooth |
LCD, application via Bluetooth |
| EMC |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-11, EN 61000-3-12 |
| Safety Standards |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
IEC 62109-1 / 2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1, 2, 14, 30) |
| Grid Standards |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |
VDE V 0124-100, VDE-AR-N 4105, CEI 0-21, CEI 0-16, UNE 206 007-1, EN 50549, G98 / G99, EN 50530 |